 |
|
Please Read these
INSTRUCTIONS
before filling your biOrb
with water
biOrb is not a toy.
Adult supervision is recommended during installation and
activation by children.
Do not expose to direct sunlight when full of water as
concentrated rays can cause a fire.
|
 Unpack
and position the biOrb.
Carefully remove all packaging. Place biOrb on a strong and level
surface (it weights 30kg full). Avoid locations where the bowl
could be knocked over.
Remember the biOrb needs a power socket within reach (follow instructions
supplied with the air pump).
biOrb
is an aquarium, water may besplashed or spilt, therefore:
Don't position the biOrb on or above items that are
electrical or could be damaged by water.
Don't
place biOrb near sources of heat such as radiators, powerful lamps
or in hot conservatories.
Don't place biOrb in direct sunlight such as on a windowsill.
Never move biOrb full of water. (Remember it weighs 30 kg when
activated).
|
|
|
Air tube, pump and filter cartridge assembly
Attach the air hose from biOrb's base connection to the
Air pump following Air pump instructions.
Ensure biOrb is located close to an electrical socket.
Do not plug in until set up procedure
completed.
Remove transit tape from Bubble Tube lid.
Your first Filter cartridge is already
fitted. |
| |
|
|
|
|
|
The filter cartridge should be changed every
1-2 months.
New filter cartridges are supplied with in the Service
Kit (purchased separately).
To replace: twist and lift bubble tube out of the biOrb.
Detach bubble tube from old filter cartridge.
Offer up new filter cartridge to bubble tube and twist
in the direction of the arrow ensuring all four cartridge
tans are fully locked (A).
Ensuring no fish are in the way, insert Bubble Tube and
Cartridge assembly into filter base.
Twist until cartridge is captive in base i.e. cannot be
pulled upwards (B).
|
| |
|
|
|
|
|
Filling and activating
Tip the Ceramic Media from it's plastic bag into a sieve
and rinse thoroughly over a sink (C). This removes dust
particles created during transit.
Discard any particles smaller than a pea.
Place the Ceramic Media by hand (D) around the Filter
Base being careful not to allow any to lay on top of the
bubble tube lid.
Don' tip the ceramic media in or out of the biOrb as it
will produce scratching. Always remove by hand.
|
| |
|
|
|
|
|
Use only ceramic media
provided by Reef One.
|
| |
|
|
|
|
|
Add the water slowly (E).
For best results only fill the bowl to about 2 inches
above the central bubble tube.
Empty the sachet of Water Treatment into the water.
Plug the air pump into the power point and switch on power.
Always use a residual current breaker with aquarium products
(not provided).
Note: The pump should be left running 24hrs a day.
Wait for about one hour before emptying sachet of Stress
Zyme in to the biOrb.
Your biOrb is now activated.
Bubbles and dust forming on the inside of the bowl during
the first 24hrs in normal and can be removed by gently
brushing with fingertips.
Wait 24hrs before adding your first
fish.
|
Servicing
Every 1-2 months a Reef One SERVICE KIT will be required to maintain
the water in prime condition. Replacement of the dirty filter cartridge
and a 30% partial water change is essential to reduce nitrate and
phosphate pollution in the water. The SERVICE KIT, available separately,
contains a filter cartridge, water chemicals, cleaning pad and
instructions. A Reef One CLEANER PUMP is available which provides
a convenient way to remove debris and siphon out the water. Never
remove the ceramic media after the biOrb has matured.
Every 24 weeks check that the one way valves
are working correctly.
Disconnect the airline tube from the air pump and lower the airline to a level
below the biOrb water line. If water leaks into the airline wither the replace
the one way valve in the biOrb base or fit an additional one way valve in the
airline 6 inches from the air pump.
Air pumps will wear out and become
noisy due to continuous operation. It is vital that they are replaced
immediately after failure to avoid water quality problems.
The air stone, in the base of the
biOrb, will become blocked after a time by calcification. The flow
of bubbles into the biOrb will be reduced and the air stone should
be replaced.
Green water is caused by harmless
algae, which occurs naturally in healthy aquariums. If your aquarium
water quickly turns green it is most likely caused by too much
sunlight, overfeeding, too many fish or high levels of nitrate
and phosphate in tap water.
Cleaning the biOrb requires care to prevent scratching. NEVER
USE HOUSEHOLD DETERGENTS, polishes or scouring pads. Reef-One cleaning
pads are available. The external acrylic surface can be polished
using a proprietary SOLVENT FREE furniture polish, which should
be applied with a soft, clean cloth and not sprayed directly onto
the biOrb.
biOrb is subject to the Registered Design Act 1949
and has Pending Patent Protection.
biOrb is a registered trademark of Reef One Ltd. |